VI DOOR LOCK MONITOR

See the door sequence—not just a final state.

DCL. DOL. Gate. Interlock. Door Zone. One validated diagnostic picture.

The VI DLM interprets configured door and lock signals as deterministic states and event sequences, preserving technician-facing DLM-F diagnostics.

Door-state truth

The VI DLM uses DCL and DOL together rather than assuming a single limit proves physical door position.

DCLDOLVI state
ONOFFFully Open
ONONTraveling
OFFONFully Closed
OFFOFFInvalid / discrepancy
CURRENT PUBLIC LANGUAGE

DLM-F001–F016

Conditions cover invalid door state, premature Gate/Interlock proving, limit changes outside Door Zone, DOL/DCL discrepancy, direction conflict and Gate/Interlock loss outside Door Zone.

A DLM code reports the condition VI observed. Field verification is still required before assigning a failed component.

SEQUENCE MATTERS

One event can explain the next.

Example: DLM-F011 → DLM-F013.

The supported sequence can show Gate proving prematurely during closing, a reopening response, DOL breaking as reopening begins, then Gate remaining made at that transition. VI is designed to preserve that chronology.

Closing→Premature Gate→Reopen→DOL Break→Gate Remains Made
INTERACTIVE DLM SEQUENCE LAB

Follow the door evidence through the sequence.

Website simulation only — it demonstrates VI diagnostic logic, not a live elevator.

VI DOOR LOCK MONITORFULLY OPEN
DCLON
DOLOFF
GATEOPEN
DOOR ZONEON
VI EVIDENCEValidated Fully Open state

DCL ON + DOL OFF corresponds to the VI Fully Open state.

SEQUENCE INTERPRETATION

Validated door state

1
OBSERVE

DCL and DOL are evaluated together.

2
CORRELATE

Gate, Interlock and Door Zone add operating context.

3
VERIFY

The mechanic verifies physical state before assigning a failed device.

SEQUENCE REPLAY · SIMULATED

Watch the event unfold.

Illustrative timing and transitions. No connection to operating equipment.

EVENT 1 / 4T + 0.00 s

State observed

Choose a scenario to replay a simulated event.